DST-80
发布日期:2021-03-03 浏览次数:2230

		
	
		DST-80 circular countercurrent glass fiber reinforced plastic cooling tower
 
	
Brief description
The circular countercurrent cooling tower adopts countercurrent gas-heat exchange technology to achieve cooling effect.Cooling tower adopts anti-corrosion design,no wearing parts,very low repair rate,design service life of 30 years.The main body is made of glass fiber reinforced plastic(FRP),and the tower body is free from corrosion.The steel structure is made of national standard material and hot-dip galvanizing is anticorrosive.The packing is made of new modified PVC material,and the structure is inclined folding packing.The water pouring area is diffused.The water is evenly distributed and the cooling effect is enhanced by rotating atomizing water distribution method.
Our company according to nearly 20 years of manufacturing experience,the structure design of this series of products made partial improvement,so that its operation is more stable and reliable,the main body is durable,assembly is more convenient,the maintenance rate is very low.The company put an end to the"extensive"production management,the implementation of standardized production,product highly mechanized operation.Products are widely used in petroleum,chemical,smelting,rubber,food,air conditioning,injection molding,pharmaceutical,brewing and other industries of circulating water cooling process.
		
	
Circular countercurrent glass fiber reinforced plastic cooling tower
		 
		 
							Quick fix
						
			
				
 
	
					 
				
						Type 
					
					
						Flow 
					
					
						Dimensions(mm) 
					
					
						Fan diameter 
					
					
						Electric power 
					
					
						net weight 
					
					
						Running heavy 
					
					
						Noise 
					
					
						Piping specifications 
				
					
					 
				
						(m3/h) 
					
					
						Diameter 
					
					
						Height 
					
					
						(mm) 
					
					
						(kw) 
					
					
						DRY 
					
					
						WET 
					
					
						db(A) 
					
					
						Water ingress 
					
					
						Effluent 
					
					
						Full of water 
					
					
						Sewage 
					
					
						Float 
					
					
						 
				
					 
				
						DS-100T 
					
					
						78.1 
					
					
						2700 
					
					
						2400 
					
					
						1450 
					
					
						2.2 
					
					
						450 
					
					
						1650 
					
					
						64.5 
					
					
						125 
					
					
						125 
					
					
						25 
					
					
						25 
					
					
						20 
					
					
						 
				
					
					 
				
						DS-125T 
					
					
						97.5 
					
					
						2700 
					
					
						2400 
					
					
						1450 
					
					
						2.2 
					
					
						540 
					
					
						1740 
					
					
						65.5 
					
					
						125 
					
					
						125 
					
					
						25 
					
					
						25 
					
					
						20 
					
					
						 
				
					
					 
				
						DS-150T 
					
					
						117 
					
					
						3000 
					
					
						2550 
					
					
						1450 
					
					
						4 
					
					
						580 
					
					
						1780 
					
					
						66 
					
					
						150 
					
					
						150 
					
					
						25 
					
					
						25 
					
					
						20 
					
					
						 
				
					
					 
				
						DS-175T 
					
					
						136.8 
					
					
						3300 
					
					
						2750 
					
					
						1750 
					
					
						4 
					
					
						760 
					
					
						1860 
					
					
						66 
					
					
						150 
					
					
						150 
					
					
						25 
					
					
						25 
					
					
						20 
					
					
						 
				
					
					 
			
		
						DS-200T 
					
					
						156.2 
					
					
						3300 
					
					
						2750 
					
					
						1750 
					
					
						4 
					
					
						780 
					
					
						1880 
					
					
						66 
					
					
						150 
					
					
						150 
					
					
						25 
					
					
						25 
					
					
						20 
					
					
						25 
				
					
		
	
Cooling tower structure
		 
		 
							Steel structure
						 
							 
							This series of cooling towers adopts an anti-corrosion design,and a large number of galvanized parts are used in the internal steel structure so that the internal structure has no corrosion parts and the equipment life is greatly extended.It saves the necessary maintenance costs and directly reduces the cost of the enterprise.The steel parts in the tower are motor brackets,packing brackets,center tubes,etc.The anti-corrosion problem is an important part of the quality assurance of the entire tower.To ensure quality,all the factory steel components are hot-dip galvanized for anti-corrosion treatment.
						 
							 
							  Packing is an important part of the cooling tower,and its efficiency depends on the degree of full contact between the cooling water and air in the packing.Our company uses multi-corrugated packing,which has a large water redistribution capacity,low resistance,and good thermal performance.The air can quickly take away the heat in the water.The unique filler flow channel enables the water flow to form a large area of flowing water film on the surface of the filler,prolongs the cooling time of the water in the filler,and improves the water cooling effect.The material is a new modified PVC material with a temperature resistance of 65°C.The performance of this product complies with the Ministry of Energy NDGJ88-89"Cooling Tower Plastic Sprinkling Filling Technical Regulations".
						 
							
			
				
					 
				
						Heading 
					
					
						Directions 
				
					
					 
				
						 
					
						 
				
						
						
					 
				
						FRP shell 
					
					
						  It adopts a glass fiber reinforced plastic shell,the overall thickness is 5mm,and the flame retardant oxygen index is≥40.Fully automatic spraying equipment is used for one-time production and molding.The product is beautiful and contains a large amount of glue.The shortcomings of uneven thickness and uneven density of hand-made cracks are eliminated.The material is made of 191#anticorrosive resin and fiber cloth and fiber felt produced by Shandong Fiberglass Group. 
				
					
					 
				
						Waterproof motor 
					
					
						  It adopts waterproof,moisture-proof,corrosion-resistant special Y series outdoor cooling tower motor,which has good sealing performance and is widely used in cooling tower environments under various conditions.The insulation class is F,the protection class reaches IP55,the motor working voltage is 380V,and the rated frequency is 50Hz. 
				
					
					 
				
						Cooling fan 
					
					
						  The airfoil type axial flow fan designed for the Department of Engineering Mechanics of Tsinghua University,the blade is made of aluminum alloy,and the blade adopts an adjustable hub,which can be angled according to the requirements.Reasonable aerodynamic force,high efficiency,large air volume,low noise,and corrosion resistance.The designed service life is 15 years. 
				
					
					 
				
						Water distribution system 
					
					
						  The rotating water distributor is used to distribute water,and the water distribution system has anti-clogging performance.The rotor is made of the aluminum alloy at one time,with a temperature resistance of 120℃.The working pressure is between 0.03-0.08mpa(that is,the head of 3-8 meters).This form of uniform water distribution and high heat dissipation efficiency.Sprinkler pipe material PVC 
				
					
					 
				
						Cloth water turn head 
					
					
						  With the use of a pipe-type water distribution system,the water distribution system has an anti-clogging performance. 
				
					
					 
				
						Thermal filler 
					
					
						 
				
						
					 
				
						Pipe diameter 
					
					
						  Inlet pipe diameter,outlet pipe diameter,automatic water replenishing ball valve,overflow port 
				
					
					 
			
		
						Ladder outside the tower 
					
					
						  The cooling tower is equipped with a climbing ladder,which is convenient for daily inspection and maintenance. 
				
					
Motor related parameters are introduced 
	
Motor insulation class
		 
		
			
				
 
	
					 
				
						Insulation temperature class 
					
					
						Rank A 
					
					
						Rank E 
					
					
						Rank B 
					
					
						RankF 
					
					
						Rank H 
				
					
					 
				
						Allowable temperature(℃) 
					
					
						105 
					
					
						120 
					
					
						130 
					
					
						155 
					
					
						180 
				
					
					 
				
						Winding temperature rise limit(K) 
					
					
						60 
					
					
						75 
					
					
						80 
					
					
						100 
					
					
						125 
				
					
					 
			
		
						Performance reference temperature(℃) 
					
					
						80 
					
					
						95 
					
					
						100 
					
					
						120 
					
					
						145 
				
					
		
 
	
The motor protection grade reaches IP55
IP (Ingress Protection) PROTECTION level system is drafted by the IEC (International Electrotechnical Commission). Electrical appliances are classified according to their dust - proof and moisture - proof properties. IP protection grade is composed of two numbers, the first number represents the lamp from the dust, to prevent the invasion of foreign objects, the second number represents the lamp against moisture, waterproof invasion of the airtight degree, the greater the number means that the protection grade is higher. The meaning of the first number: 0: no protection, no special protection 1: the protection of the solid more than 50mm, can prevent the diameter of more than 50mm of solid foreign bodies into the shell. It can prevent a large area of the human body (such as the hand) from accidentally or accidentally touching the charged or moving part of the shell, but can not prevent the conscious approach to these parts 2: protection of solids greater than 12mm, can prevent the diameter of the larger than 12mm of solid foreign bodies into the shell. Can prevent fingers from touching the charged or moving part of the shell ①3: protection of more than 2.5mm of solid, can prevent the diameter of more than 2.5mm of solid foreign bodies into the shell. Can prevent the thickness or diameter of more than 2.5mm tools, metal wire and so on touching the charged or moving part of the shell ①②4: protection of more than 1mm of solid, can prevent the diameter of more than 1mm of solid foreign bodies into the shell. Can prevent the diameter or thickness of more than 1mm wire or strip touching the live or running part of the shell ①②5: dustproof, can prevent dust from entering to affect the normal operation of the product, completely prevent touching the live or moving part of the shell. 6: dust tight, can completely prevent dust from entering the shell, completely prevent hit shell charged or exercise part of the meaning of the second number: 0: no protection, there is no specific protective 1: drip-proof, vertical drop of water should not go into the motor internal 2:15 o drip-proof, with a plumb line into 15 o Angle within the scope of drop water, should not directly into the motor internal 3: water spray, water and the plumb line into 60 o Angle within the scope of the spray water, should not go into the motor internal 4: splash, splash water on any direction motor should be no harmful effects 5: water spray, spray any direction for motor should be no harmful effects 6: Prevent water waves or impose, violent waves or strong water should be no harmful effects on the motor 7: flooding, motor under pressure and time stipulated in the submerged in the water, the water inflow should be no harmful effect on 8: scuba diving, motor in the provisions under the pressure of the long soak in the water, the water inflow should have no harmful effects commonly used in the application of motor protection grade IP11, IP21, IP22, IP23, IP44, IP54 or IP55, etc.
		
	
		
	
		
	
		
	
		
	
		 
  
	