[Anhui Dingsheng Square Counterflow Cooling Tower|Industrial Cooling|Square Fiberglass Cooling Tower]Description:
1.Standard design conditions of square counterflow cooling tower:dry bulb temperature 31.5℃,wet bulb temperature 28℃,atmospheric pressure 99400Pa,inlet water temperature 42℃,outlet water temperature 32℃;
2.Adopting airfoil hollow structure,large diameter,large area,low speed,low dynamic pressure glass fiber reinforced plastic fan blades,the use of this type of cooling tower has the obvious characteristics of energy saving and low noise;
3.It can be combined in various forms in parallel,which is more suitable for the use of large-volume circulating cooling water systems;
4.The low-noise cooling tower is equipped with noise reduction devices at the air inlet and outlet and rain shower area so that the cooling tower of the same level can effectively reduce the noise by 5dB(A);
5.The special packing for oblique trapezoidal wave square tower is selected,which has excellent thermal performance and low ventilation resistance so that this type of cooling tower can achieve the design purpose of compact structure and small floor space;
6.BO-160/45 asymmetric water collector device is installed on the water distribution pipe,the water collection effect is obvious,and the floating water loss of the cooling tower is reduced to less than 0.01%;
7.The fixed water distribution system is adopted,and the ABS multilayer flow low-pressure sprinkler nozzle is selected.The water distribution is uniform,the service life is long,and the water distribution head is low,which is conducive to saving the water distribution power of the system;
8.The structure is stable,and the maintenance platform is set on the top of the tower,which makes maintenance and repair more convenient;
9.The tower frame can be made of Q-235 profiles,304 stainless steel profiles,and FRP profiles.The"304/FRP"frame can be used in acidic environments where the pH of the circulating water is as low as 1.0;
10.If the turbidity of the circulating water is higher than 50ppm for a long time or contains impurities such as oil,you need to choose PVC grid packing or 304 stainless steel hanging plate to fill according to the water quality conditions.The turbidity of the circulating water can be extended to 450ppm;
11,the cooling tower frame with a water volume of 800m3/h can use a reinforced concrete frame.Although the frame has a slightly longer construction period and higher one-time investment,it has a long service life and low maintenance costs.Users can choose according to the actual situation;